Status LED indicators of Dell PowerEdge R660

 In this article we will introduce you in detail the Status LED indicators of Dell PowerEdge R660. The unique Express Service Code and Service Tag are used to identify the system.

 Status LED indicators

Table 1. Status LED indicators and descriptions

ICONDESCRIPTIONCONDITIONCORRECTIVE ACTION
07211Drive indicatorThe indicator turns solid amber if there is a drive error.Check the System Event Log to determine if the drive has an error.
Run the appropriate Online Diagnostics test. Restart the system and run embedded diagnostics (ePSA).
If the drives are configured in a RAID array, restart the system, and enter the host adapter configuration utility program.
07212Temperature indicatorThe indicator turns solid amber if the system experiences a thermal error (for example, the ambient temperature is out of range or there is a fan failure).Ensure that none of the following conditions exist:
  • A cooling fan has been removed or has failed.
  • System cover, air shrouds, or back filler bracket has been removed.
  • Ambient temperature is too high.
  • External airflow is obstructed.
07213Electrical indicatorThe indicator turns solid amber if the system experiences an electrical error (for example, voltage out of range, or a failed power supply unit (PSU) or voltage regulator).Check the System Event Log or system messages for the specific issue. If it is due to a problem with the PSU, check the LED on the PSU. Reseat the PSU.
07214Memory indicatorThe indicator turns solid amber if a memory error occurs.Check the System Event Log or system messages for the location of the failed memory. Reseat the memory module.
07215PCIe indicatorThe indicator turns solid amber if a PCIe card experiences an error.Restart the system. Update any required drivers for the PCIe card. Reinstall the card.